Cyanogen bath has alkaline zincate bath, ammonium bath, sulfate bath and ammonia chloride bath. Cyanide galvanized solution plating ability is good, the coating lubrication, in production has been selected for a long time, steel mesh chromium plating: chromium plating layer has a high hardness, according to the bath composition and process conditions are different, the hardness can be changed in a large scale 400~1200HV.
There are many kinds of galvanized solution, which can be divided into cyanide plating solution and cyanide plating solution. Cyanide galvanizing solution has good dispersion and covering ability, coating crystallization is smooth and fine, simple operation, wide application range, has been used in production for a long time. However, because the plating solution contains highly toxic cyanide, the gas escaping in the plating process is harmful to the health of workers, and the waste water must be treated strictly before discharge.
The barbed rope is twined and braided to save transportation space. It is usually wound into bundles.
- Correction is the hot galvanized wire or cold galvanized wire secondary treatment, the surface after correction is smooth and shiny, and the tensile strength is stronger, so that it is not easy to break. Now it is usually used for screen industry will be changed, which can improve the quality. In addition, clothes rack, communication, high voltage line will be changed to prevent breakage.
In the calculation process of 12*14 specifications of barbed rope, it can not be calculated according to the above calculation formula, because first of all, two specifications of raw materials are used, the thinner the wire diameter, the higher the processing cost. Generally speaking, a kilogram of 12*14 barbed rope can reach about 7.5 meters, and the ratio of warp wire to barbed rope cannot be calculated according to the traditional ratio of 7 to 3. The specific use of how much wire and silk need to go through a series of professional measurement but also increase the loss of raw materials and other factors to calculate. Thorn rope factory will also according to customer needs to calculate the reasonable amount of customer use.
Post time: 17-08-22After passivation treatment of galvanized layer, a layer of bright old and beautiful color passivation film can be generated, which can significantly improve its protective performance. There are many kinds of galvanized solution, which can be divided into cyanide plating solution and cyanide plating solution. Cyanide galvanizing solution has good dispersion and covering ability, coating crystallization is smooth and fine, simple operation, wide application range, has been used in production for a long time.
The service life of the original galvanized iron welding mesh is very limited. Generally, good iron railings can only be used for about 2 years, and then renovated until the service life, which is not only time-consuming but also has safety risks. After the appearance of zinc-steel railings, the service life has been increased to a great extent in the post-processing. Generally, it can be used for at least 20 years. To improve the service life of zinc steel railings, we first have a brief understanding of the product characteristics of railings. Then from the maintenance aspect, it is necessary to maintain. Maintenance method of electric welding mesh:
B. When the thickness of the plating is greater than 4 mm, the zinc adhesion should not be less than 610g/m, that is, the average thickness of the zinc layer should not be less than 86 microns.
- Annealed wire is a kind of soft iron wire made of low carbon steel by cold drawing, heating, constant temperature and heat preservation. The composition of the wire varies according to its use. It contains iron, cobalt, nickel, copper, carbon, zinc, and other elements. The hot metal billet is rolled into 6.5mm thick steel bar, that is, the wire rod, and then it is put into the wire drawing device to draw the wire of different diameter, and gradually reduce the aperture of the drawing disk, cooling, annealing, plating and other processing technology to make a variety of different specifications of the wire.
Post time: 31-01-23- Zinc dipping time should be adjusted according to the thickness of wire diameter. The method of adjustment is to use the lead screw above the zinc pot, the length of the distance to the ceramic sinking roller. Thick wire diameter zinc dipping time should be long, fine wire diameter zinc dipping time should be short, zinc dipping length is in the range of 2~3.5m, which is also to reduce the zinc consumption of steel wire, is an aspect of maintaining the uniformity of zinc layer.
First of all, we need to pay attention to the material of the barbed wire, because the galvanized barbed wire itself includes cold plating and hot plating. The properties and prices of the two are obviously different, and it is easy to be confused by a little negligence.
There is good toughness and elasticity, simply put, can be easily made into various shapes, and zinc as a coating is silver, very beautiful. Such characteristics make hot dip galvanized wire handicrafts, woven screen and other aspects have also been applied. Hot plating wire selection of high quality low carbon steel rod processing, is the selection of high quality low carbon steel, after drawing molding, pickling rust removal, high temperature annealing, cooling and other processes.
- Correction is the hot galvanized wire or cold galvanized wire secondary treatment, the surface after correction is smooth and shiny, and the tensile strength is stronger, so that it is not easy to break. Now it is usually used for screen industry will be changed, which can improve the quality. In addition, clothes rack, communication, high voltage line will be changed to prevent breakage.
(2) Packing and binding galvanized shaft wire order notes: ① the galvanized iron wire shall not be damaged when the tightening. (2) Stop the use of more than two strands of galvanized iron wire around the operation method. ③ The diameter of galvanized wire for pulling should not be less than 4mm, and the diameter of galvanized wire for binding should not be less than 2.6mm. (4) Galvanized iron wire shall not be used as waist hoop down reinforcement, usually not used as a whole binding. Warehouse galvanized wire is mainly used to block and distinguish the function of the area, warehouse galvanized wire is one of the primary use of galvanized wire, warehouse galvanized wire primary layout features are as follows: layout: Column mesh frame, column to choose square steel pipe, galvanized wire frame is also a small square pipe as the data, column and mesh frame corresponding direction are welded connecting ear piece (flat iron), column and mesh frame through the connection of the ear piece bolt fixed, column bottom welding plate, column bottom plate through expansion bolts and fixed on the ground.
Large coil galvanized wire in the zinc immersion distance debugging, keep the original speed unchanged, according to t= KD to determine the zinc immersion time (1), where: t is the zinc immersion time is constant, take 4-7D is the diameter of steel wire mm, and then estimate the zinc immersion distance. By adjusting the zinc dip distance, the zinc dip time of steel wire of various specifications can be shortened by 5s on average. In this way, the zinc consumption per ton of steel wire decreases from 61kg to 59.4kg.
Barbed wire production of general selection of low carbon iron wire, after fine and accurate active welding equipment processing, the selection of galvanized process surface treatment. After the completion of the product, the net surface is smooth and regular, good integrity, strong consolidation, even if part of the trade-off or under pressure will not appear lax phenomenon.
Post time: 24-05-23